Variable Frequency Drives for Async Injection Molding Machine



1. Information of Product Model



ES101 Series Variable Frequency Drives are cabinet-type drives, and hence can be located directly on the ground. The cabinet inside is equipped with mains frequency and variable frequency switch contactor. Working status of mains frequency and variable frequency can be manually switched by the key rotary switch on cabinet panel. 



The cabinet inside is equipped with analog sampling interface card EPC-IM1 dedicated for injection molding machine.



2. Table 1 shows ES101 Series Variable Frequency Drives model and technical data.



Table 1 Product model and technical data

























































































Model




Power Rating(kW)




Rated Output Current (A)




Rated Input current (A)




Applicable motor (kW)




ES101-4T11B




11




24




29




11




ES101-4T15B




15




30




35




15




ES101-4T18.5




18.5




39




44




18.5




ES101-4T18.5B




18.5




39




44




18.5




ES101-4T22




22




45




50




22




ES101-4T22B




22




45




50




22




ES101-4T30




30




60




65




30




ES101-4T30B




30




60




65




30




ES101-4T37




37




75




80




37




ES101-4T37B




37




75




80




37




ES101-4T45




45




91




95




45




ES101-4T45B




45




91




95




45




ES101-4T55




55




112




118




55




ES101-4T55B




55




112




118




55




ES101-4T75




75




150




157




75




ES101-4T75B




75




150




157




75



3. Technical Features of ES101 Variable Frequency Drives



Table 2 Technical features



























































































  Power input


Rated input voltage




3-phase AC208V/AC220V/AC230V/AC240V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V




Rated input current




See Section 2.3




Frequency




50Hz/60Hz, tolerance ±5%




Allowable range of voltage




Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;




Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC61800-2




Power output




Applicable motor (kW)




See Section 2.3




Rated current (A)




See Section 2.3




Output voltage (V)




3-phase: 0~ rated input voltage, error < ±3%




Output frequency (Hz)




0.00~ 600.00Hz; unit: 0.01Hz




Overload capacity




150% - 1min; 180% - 10s; 200% - 0.5s




Control characteristics




V/f patterns




V/f control




Sensor-less vector control 1




Sensor-less vector control 2




Close-loop vector control




Speed range




1:100 (V/f control, sensor-less vector control 1)




1:200 (sensor-less vector control 2)




1:1000 (close-loop vector control)




Speed accuracy




±0.5% (V/f control)




±0.2% (sensor-less vector control 1 & 2)




±0.02% (close-loop vector control)




Speed fluctuation




±0.3% (sensor-less vector control 1 & 2)




±0.1% (close-loop vector control)




Torque response




< 10ms (sensor-less vector control 1 & 2)




< 5ms (close-loop vector control)




Torque control accuracy




±7.5% (sensor-less vector control 2)




±5% (close-loop vector control)




Starting torque




0.5Hz: 180% (V/f control, sensor-less vector control 1)




0.25Hz: 180% (sensor-less vector control 2)




0Hz: 200% (close-loop vector control)




Basic functions




Start frequency




0.00~ 600.00Hz




Accel/Decel time




0.00~60000s




Carrier frequency




0.7kHz~16kHz




Frequency command sources




Digital setting + keypad ∧/∨




Digital setting + terminal UP/DOWN




Communication




Analog setting (AI1/AI2/AI3)




Terminal pulse setting




Motor started methods




Started from starting frequency




DC brake then started




Speed search started




Motor stopped methods




Ramp to stop




Coast to stop




Ramp to stop + DC brake




Basic functions




Dynamic brake capacity




Brake unit threshold voltage: 650V~750V; service time: 0.0~100.0s;




DC brake capacity




DC brake start frequency: 0.00~600.00Hz




DC brake current: 0.0~100.0%




DC brake time: 0.0~30.00s




Input terminals




7 digital inputs, one of which can be used for high-speed pulse input. Compatible with    active open collectors NPN, PNP and dry contact input.




3 analog inputs, one of which supports voltage input only, and the other two are    voltage/current programmable.




Output terminals




One high-speed pulse output terminal, 0~50kHz square signal; can output command frequency, output frequency and so forth




One digital output terminal




Two relay output terminals




Two analog output terminal, voltage/current programmable; can output command frequency,    output frequency and so forth




Encoder signal terminal




Compatible with 5V/12V encoder




Compatible with different types of encoder signal input, such as open collector, push-pull    and differential, etc.




Protection function

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 
Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed